How it works

Garden Building & Garage Base Guide (2026): Free UK Guide + Prep Checklist PDF

By the VeltHaven Team · Last updated: 21 October 2026

Insulated garage at golden hour with an anthracite door beside a clipped hedge

The base is the one part of a garden building nobody photographs, nobody asks about, and everybody discovers the price of late. It sits under the headline figure on most suppliers’ websites, gets quoted separately after you’ve already decided, and — if it’s wrong — quietly ruins the building standing on it.

This guide covers the three base types you’ll be choosing between, what thickness and concrete grade suits your building, and the details that decide whether a slab lasts thirty years or cracks in three. You can download our base-prep checklist as a PDF, free, to keep beside you while you plan the site — jump straight to the download.

It’s general guidance for UK homeowners rather than an engineering specification for your particular plot — soil, slope and drainage vary too much for that, and your final design should be confirmed by a structural engineer or your groundwork contractor. The full VeltHaven detail lives on our Foundation & Groundwork page; this is the plain-English walkthrough of the same facts.

What goes wrong, and how long it takes to show

Base failures are rarely dramatic. What usually happens is that one corner settles a few millimetres over a couple of winters, and the building starts telling you about it: a door that needs a shove in January, a sliding glass wall that runs unevenly, a hairline crack that turns into a damp patch along one wall.

By then the fix is expensive, because the building is on top of it.

A base has three jobs. It spreads the building’s weight so the ground beneath compresses evenly instead of in patches. It keeps ground moisture out of your floor. And it stays dead level and square, which is what keeps doors, windows and glazing running true years later.

Everything below is in service of those three things.

The three base types

Concrete slab. A reinforced, dead-level pad, sized to the building, over a compacted sub-base with a damp-proof membrane underneath. It suits most ground types and it’s what most garages and garden rooms end up on — heavier buildings especially.

Strip footing. Concrete poured into perimeter trenches so the walls carry down onto firmer ground below the topsoil. More digging and more concrete than a slab, and it earns that on larger or heavier garages, or on softer ground that needs the extra support.

Ground screws. Steel screws driven into the ground to form a platform. No concrete, no curing time, no permanent change to the garden, and they handle slopes well. Worth considering if you might want the building gone again one day, or if the site would need serious levelling for a slab.

Whichever you choose, the same fundamentals apply: dead level, square to the building’s exact dimensions, no fall across the base itself, ground that drains water away from the building, a damp-proof membrane under any slab, and full curing time before anything gets built on it.

What size building needs what base?

Two families. Steel garages sit on a standard slab. Insulated garages and garden rooms sit on an insulated slab — and garden rooms get the thinnest slab, because they carry no vehicles. This is the specification we work to; the full detail and costs are on our Foundation & Groundwork page.

Steel garages — standard base

Building & useSlabConcreteMesh
Cars and storage125 mm (100 mm absolute minimum)C25/30A142
Double door, SUV or VAN height, 4x4s or vans150 mmC30/37A193
Workshop, car lift or heavy equipment150 mm minimum; an engineer checks the lift posts, at extra costC32/40A252

Insulated garages and garden rooms — insulated base

Building & useSlabConcreteMeshInsulation under the slab
Garden room, no vehicles100 mmC25/30A142100 mm rigid floor insulation rated by its maker for use under a concrete slab (XPS, or a floor-grade EPS); 150 mm if the building is heated every day
Insulated garage, cars and storage150 mmC30/37A193100 mm XPS (≥300 kPa) or an equivalent rated for vehicle loads; 150 mm if the building is heated every day
Insulated garage, workshop, car lift or heavy equipment150 mm minimum; an engineer checks the lift posts, at extra costC32/40A252As for cars and storage
Any heated building of 50 m² or moreAs aboveAs aboveAs aboveRequired by the Building Regulations energy-efficiency rules (Part L); building control confirms the thickness for your site

The exact thickness and reinforcement are confirmed for your ground and your load. This table is our default, not an engineering design. If poor ground needs an engineer to check it, that is an extra cost.

Concrete grades read as “C25/30” — the two numbers are strength measures your supplier will recognise. You don’t need to understand them, only to quote the grade to whoever is mixing or pouring, and to notice if a quote doesn’t mention one at all.

Get the free base-prep checklist PDF

A six-step checklist, a labelled slab cross-section, the size-to-spec table and reference CAD links. One free guide, by email.

Your guide, plus occasional emails to help with your build. Unsubscribe anytime. See our Privacy Policy.

The parts that aren’t the thickness

Thickness is the number everyone asks about. These three decide as much or more:

The threshold takes the punishment. The front edge of a garage slab absorbs vehicle loading, frost and edge impact every single day, which is why typical guidance puts 150mm at the threshold and edges even where the centre of the slab is thinner. It’s the first place a cheap base fails.

A slab is a system, not a pour. Underneath the concrete: 150 mm of compacted MOT Type 1, laid in layers (200 mm on clay or soft ground, or for vans and workshops), with sand blinding on top. MOT Type 1 is a graded crushed stone that spreads load onto the ground below. Over it goes a DPM, the plastic damp-proof membrane that stops ground moisture rising into your floor. Neither is optional, and both are invisible the moment the concrete goes down, which is precisely why they’re the corners that get cut.

Concrete needs to cure. Allow at least 7 days before the building goes up on a fresh slab. This is the one that gets compressed when a delivery date is looming, and it’s the one you can’t undo.

Do I need to insulate the base?

Under a steel garage you do not need to, unless you will heat a building of 50 m² or more. Under an insulated garage we recommend it, and under a garden room we strongly recommend it. Our insulated garages and garden rooms have 100 mm PIR walls and roof, and a bare concrete slab loses heat several times faster per square metre than those walls, so the floor becomes the weak point — and a cold slab under a warm room is where condensation forms. A garden room has no separate insulated floor: its floor finish sits straight on the base, so the base is its only floor insulation. Energy-efficiency rules (Part L) do not apply to a stand-alone non-domestic building under 50 m². A heated building of 50 m² or more must meet them, which means an insulated floor. Building control confirms this for your site.

A base is the only part of the job you genuinely cannot revisit later, so it is the wrong place to meet a minimum.

Every site is different, so the exact requirement for your building is confirmed individually, from your site photos, before anything is manufactured. If you already have a base and it meets the spec, we’ll tell you that rather than sell you another one. You can see what’s included with Steel Garages, Insulated Garages and Garden Rooms.

Does the base need planning permission?

Not usually on its own. The base itself doesn’t normally need separate planning permission in England and Wales — but the building that sits on it might, depending on its size and where it goes.

Our planning permission guide covers the height and boundary rules, and the Building Regulations guide covers when the size of the building brings a different regime into play. If you’re unsure, your Local Planning Authority will confirm it — that call is free and takes minutes.

Get the free base-prep checklist PDF

Reading this once is useful. Having a checklist in your pocket while you’re standing on the site is more useful.

The free base-prep guide PDF covers:

  • A step-by-step checklist in plain English: site check → access and services → dig and sub-base → formwork and DPM → pour and cure → handover checks.
  • Two worked cross-sections, a standard base and an insulated base, showing where the slab, reinforcement, insulation, membrane and sub-base sit relative to each other.
  • The same specification tables as above, for reference away from a screen, with a budgeting box.
  • An appendix of free, publicly available reference CAD details, for anyone who wants to see how these are conventionally drawn.

Enter your email address and we’ll send it over — no spam, unsubscribe any time.

Nothing else in this guide is gated. The PDF is free; asking for an email is simply how we hand it over.

Frequently asked questions

Do I need a concrete base for a garden room?

Not necessarily concrete. A garden room can sit on a slab, a strip footing or ground screws depending on your ground and how you’ll use the building. What all three need in common is a level, well-drained base sized correctly to the building. Our groundwork guide covers how we assess which is right for yours.

How thick should the concrete base be?

Our default is a 125 mm (100 mm absolute minimum) C25/30 slab for a steel garage used for cars and storage, a 150 mm C30/37 slab over insulation for an insulated garage, and a 100 mm C25/30 slab over insulation for a garden room, which carries no vehicles. For vans and 4x4s a steel-garage slab goes to 150 mm C30/37, and for a workshop or car lift to 150 mm minimum C32/40, where an engineer checks the lift posts, at extra cost. Every slab sits on 150 mm of compacted MOT Type 1 and a 1200-gauge damp-proof membrane. Allow at least 7 days for the concrete to cure before the building is installed. The exact thickness and reinforcement are confirmed for your ground and your load.

How long does concrete need to cure before building on it?

At least 7 days before a building goes up on a fresh slab. It’s tempting to shortcut when a delivery date is booked, and it’s one of the more expensive mistakes to correct afterwards, because correcting it means moving the building.

What is MOT Type 1, and do I really need it?

A graded crushed-stone sub-base, compacted in layers beneath the concrete. It spreads load evenly onto the ground below and helps water drain away. Skipping it, or under-compacting it, is a common reason slabs crack or settle within a few years.

What is a DPM, and where does it go?

A damp-proof membrane: a plastic sheet laid under the slab before the pour, stopping ground moisture rising through the concrete into your building. It sits between the sub-base and the concrete, lapped and sealed at every join.

Can I use ground screws instead of a concrete base?

For many garden rooms and lighter buildings, yes — they’re quick, need no digging, avoid curing time entirely and cope well with sloped or uneven gardens. Heavier garages, particularly with vehicle loads, more often want a slab or strip footing. We’ll confirm which suits your building and site.

Related reading


This guide is general information for UK homeowners, not an engineering specification for your site. Have your final base design confirmed by a structural engineer or your groundwork contractor before you dig or pour. The specification is our default, confirmed for your ground; see the appendix in the free PDF for the published UK groundworks sources behind it.

Every VeltHaven building is delivered and installed by a UK-registered company (Companies House 17261887), with the VeltHaven 10-Year Structural Warranty (2 years full warranty + structural cover to year 10). Does not affect your statutory rights.

Get the free base-prep checklist PDF

A six-step checklist, a labelled slab cross-section, the size-to-spec table and reference CAD links. One free guide, by email.

Your guide, plus occasional emails to help with your build. Unsubscribe anytime. See our Privacy Policy.

Ready to build?

Get your fixed price

Design & price online Talk to us